The human eye can appreciate approximately _______ shades of gray at a particular level.


A) 5
B) 10
C) 30
D) 300

E) All of the above
F) B) and D)

Correct Answer

verifed

verified

Histogram analysis compares the histogram with histograms specific to:


A) the x-ray equipment
B) the computer monitor
C) the patient data
D) the anatomic part being imaged

E) A) and C)
F) All of the above

Correct Answer

verifed

verified

Adjustments in window width and level allow a limited portion of the gray scale to be expanded and the gray levels differentiated in the image.

A) True
B) False

Correct Answer

verifed

verified

The manifest image:


A) is the image after exposure to exit radiation and before chemical processing
B) is the image after chemical processing
C) is the radiographic image
D) B and C

E) C) and D)
F) All of the above

Correct Answer

verifed

verified

Indirect capture cassette-less digital imaging systems use:


A) charge-coupled devices
B) photoconductors and TFT arrays
C) scintillator and TFT array
D) A and C

E) C) and D)
F) B) and D)

Correct Answer

verifed

verified

The test tool to evaluate film-screen contact is the:


A) densitometer
B) sensitometer
C) wire mesh
D) penetrometer

E) B) and C)
F) None of the above

Correct Answer

verifed

verified

The ideal expression of digital detector image resolution is the:


A) Nyquist frequency
B) MTF
C) LSR
D) DQE

E) A) and C)
F) A) and B)

Correct Answer

verifed

verified

With cassette-less digital radiography,the detector array:


A) is used exactly like a cassette
B) replaces the bucky assembly
C) transfers the digital data directly to a computer
D) B and C

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

The fixing stage:


A) hardens the emulsion
B) removes unexposed silver halide crystals
C) makes the image permanent
D) all of the above

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

Which of the following cassette-less digital image receptors does not use a network of TFTs?


A) indirect capture with CCD
B) indirect capture with amorphous silicon photodetector
C) direct capture with amorphous selenium photoconductor
D) none of the above use TFTs

E) All of the above
F) B) and D)

Correct Answer

verifed

verified

As compared with the H&D curve of film with the toe,straight-line portion,and shoulder,the response of a digital IR to exposure is:


A) more curved
B) a straight line
C) a line and a curve
D) a curve but less than film

E) A) and B)
F) B) and C)

Correct Answer

verifed

verified

As the matrix size decreases,the spatial resolution:


A) increases
B) decreases
C) remains the same
D) none of the above

E) A) and B)
F) All of the above

Correct Answer

verifed

verified

The rare earth phosphors are used in the intensifying screen to:


A) protect the active layer
B) convert x-rays to light photons
C) convert light photons to x-rays
D) provide physical support for the active layer

E) A) and B)
F) All of the above

Correct Answer

verifed

verified

For cassette-based digital systems,the EI is based on:


A) how much exposure leaves the x-ray tube
B) how much mAs was set at the operators console
C) the histogram analysis
D) the kVp being used

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Lead foil may be located in the ___________ of a film cassette to prevent backscatter from reaching the film.


A) front
B) back
C) middle
D) none of the above

E) B) and D)
F) C) and D)

Correct Answer

verifed

verified

The range of exposure intensities that an IR can respond to and acquire image data is:


A) dynamic range
B) exposure range
C) brightness range
D) all of the above

E) A) and C)
F) None of the above

Correct Answer

verifed

verified

Having a reflective layer in an intensifying screen results in the screen having a(n) ________ screen speed.


A) slower
B) faster
C) identical
D) none of the above

E) A) and D)
F) C) and D)

Correct Answer

verifed

verified

__________ is the standard format for digital medical images.


A) PACS
B) DICOM
C) teleradiology
D) RIS

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

The purpose of film processing is to convert the _______________ image to the __________________ image.


A) manifest;manifest
B) manifest;latent
C) latent;manifest
D) latent;latent

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

_______________ is a flat metal surface that helps to align the film as it enters the processor.


A) recirculation
B) the feed tray
C) the standby control
D) replenishment

E) B) and C)
F) All of the above

Correct Answer

verifed

verified